Verification of bearing capacity
Verification of normal force
MURUS doesn't utilize the diagrams of the SIA266 code but rather
carries out a nonlinear calculation based on the same moment-curvature
characteristics used for creating the diagrams in the code and
accounting for second order effects. This leaves more freedom in
choosing the boundary conditions and eliminates interpolation inaccuracies.
It furthermore yields the tnom for the verification of shear that otherwise has
to be assumed to a conservative 1/4 of the thickness of the wall.
Verification of shear
The procedure makes use of the tnom supplied by the preliminary
verification of normal force. It then tries to find the stress fields for the
verification of shear. The solution is not unique as long as the bearing capacity
is not reached.
Lateral loads
Lateral loads are assumed to be transferred in vertical direction only.
They are included in the calculation model for the verification of normal force
and therefore act together with the normal forces.
Carrying capacity
It is possible to evaluate the carrying capacity factor λ, by which a variable
loading [Nx, V, Mz1, qz]Delta can be multiplied after
successfully applying a constant loading [Nx, V, Mz1, qz]Base
until the ultimate limit state is reached.
|